-40%
Fluke 414D Laser Distance Meter II Class 50m Range +/- 2mm Accuracy USA UPS ship
$ 84.45
- Description
- Size Guide
Description
Fluke 414D Laser Distance Meter, II Class, 50m Range, +/- 2mm Accuracy USA madeUPS or FedEx
FREE Shipping / Korean stock
414D
419D
424D
Distance Measurement
Typical Measuring Tolerance[1]
± 2.0 mm [3]
± 1.0 mm [3]
Maximum Measuring Tolerance[2]
± 3.0 mm [3]
± 2.0 mm [3]
Range at Leica target plate GZM26
50 m / 165 ft
80 m / 260 ft
100 m / 330 ft
Typical Range[1]
40 m / 130 ft
80 m / 260 ft
80 m / 260 ft
Range at unfavorable condition[4]
35 m / 115 ft
60 m / 195 ft
60 m / 195 ft
Smallest unit displayed
1 mm / 1/16 in
6 /30 / 60 mm
(10 / 50 / 100 m)
∅ laser point at distances
6 /30 / 60 mm
(10 / 50 / 100 m)
6 /30 / 60 mm
(10 / 50 / 100 m)
Tilt measurement
Measuring tolerance to laser beam[5]
No
No
± 0.2°
Measuring tolerance to housing[5]
No
No
± 0.2°
Range
No
No
360°
General
Laser class
2
Laser type
635 nm, <1 mW
Protection class
IP40
IP54
Automatic laser off
After 90 seconds
Automatic power off
after 180 seconds
Battery life (2 x AAA) 1.5 V NEDA 24A/IEC LR03
Up to 3,000
measurements
Up to 5,000
measurements
Size (H X W X L)
116mm Length
53mm Width
33mm Depth
127mm Length
56mm Width
33mm Depth
127mm Length
56mm Width
33mm Depth
Weight (with batteries)
113 g
153 g
158 g
Temperature range: Storage Operation
-25 °C to +70°C
(-13 °F to +158 °F)
0 °C to +40 °C
(32 °F to +104 °F)
-25 °C to +70°C
(-13 °F to +158 °F)
-10 °C to +50 °C
(14 °F to +122 °F)
Calibration cycle
Not applicable
Not applicable
Tilt and compass
Maximum altitude
3000 m
3000 m
3000 m
Maximum relative humidity
85% at 20 °F to 120°F
(-7 °C to 50 °C)
85% at 20 °F to 120°F
(-7 °C to 50 °C)
85% at 20 °F to 120°F
(-7 °C to 50 °C)
Safety
IEC Standard No. 61010-1:2001
EN60825-1:2007 (Class II)
EMC
EN 55022:2010
EN 61000-4-3:2010
EN 61000-4-8:2010
[1] Applies for 100 % target reflectivity (white painted wall), low background illumination, 25 °C.
[2] Applies for 10 to 500 % target reflectivity, high background illumination, -10 °C to +50 °C.
[3] Tolerances apply from 0.05 m to 10 m with a confidence level of 95 %. The maximum tolerance may deteriorate to 0.1 mm/m between 10 m to 30 m and to 0.15 mm/m for distances above 30 m.
[4] Applies for 100 % target reflectivity, background illumination between 10'000 lux and 30'000 lux.
[5] After user calibration. Additional angle related deviation of ±0.01° per degree up to ±45° in each quadrant. Applies at room temperature. For the whole operating temperature range the maximum deviation increases by ±0.1°.